{"id":3808,"date":"2024-04-20T02:28:22","date_gmt":"2024-04-20T02:28:22","guid":{"rendered":"https:\/\/www.hiclover.com\/?p=3808"},"modified":"2024-04-20T02:28:22","modified_gmt":"2024-04-20T02:28:22","slug":"incinerators-300-kg-per-hour","status":"publish","type":"post","link":"https:\/\/gofullday.com\/incineration\/incinerators-300-kg-per-hour\/","title":{"rendered":"incinerators 300 kg per hour"},"content":{"rendered":"<p> Guide autoclave with vertical loading; gravity displacement type with possibility for Vacuum.  <\/p>\n<p> &nbsp; <\/p>\n<p> Capacity:\u00a0\u00a0\u00a0\u00a0\u00a0 Up to 12 kg\/h <\/p>\n<p> &nbsp; <\/p>\n<p> Chamber size:\u00a0\u00a0\u00a0\u00a0\u00a0 >150 Dimensions <\/p>\n<p> &nbsp; <\/p>\n<p> Material:\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Stainless steel <\/p>\n<p> &nbsp; <\/p>\n<p> Temperature:\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 134 \u00b0C <\/p>\n<p> &nbsp; <\/p>\n<p> Additional information: <\/p>\n<p> &nbsp; <\/p>\n<p> \uf0b7Minimum autoclave room size shall be 150 liters and shall have a usable quantity (loading basket) of 100 liters.  <\/p>\n<p> \uf0b7Shall work based on gravity air displacement principle.  <\/p>\n<p> \uf0b7The vacuum system shall be of a thermal shock kind.  <\/p>\n<p> &nbsp; <\/p>\n<p> \uf0b7The pressure vessels ought to be pressure tight, the rising of the pressure (at a start pressure of below 80 mbar) <\/p>\n<p> shall be lower than one mbar\/min.  <\/p>\n<p> &nbsp; <\/p>\n<p> \uf0b7With in-build electrical heating elements for steam generation (heating elements > 4000 Kw).  <\/p>\n<p> \uf0b7Chamber and door shall be made from high quality stainless steel (e.g. AISI 3161).  <\/p>\n<p> \uf0b7Chamber in vertical position, it shall enable a simple loading\/unloading of this loading basket.   The baskets shall be made for the <\/p>\n<p> usage of non-heat resistant waste bags, a system for the collection and controlled release of free liquids and <\/p>\n<p> condensate in the waste shall be integrated.  <\/p>\n<p> \uf0b7The temperature measured at the reference measurement stage of the treatment room shall not be lower than 105\u00b0C <\/p>\n<p> (TDes 0+4).  The treatment time shall be \u226530 minutes at 105\u00b0C, \u226520 minutes using a temperature used of \u2265121\u00b0C (TDes <\/p>\n<p> 0+4) and \u226510 minutes using a treatment temperature of \u2265 134.  <\/p>\n<p> \uf0b7The steering of the treatment process should be semi-automatically in addition to manual.  <\/p>\n<p> \uf0b7The Treatment Equipment shall be equipped with the following instruments: <\/p>\n<p> o\u00a0\u00a0 treatment room temperature indicating instrument <\/p>\n<p> otreatment room pressure indicating instrument <\/p>\n<p> \uf0b7For the treatment of the outgoing air, a HEPA filter in combination with a condensation system should be used.  <\/p>\n<p> \uf0b7The filter shall be constructed in a manner that a disinfection of the filter shall be possible in an integrated condition.  <\/p>\n<p> &nbsp; <\/p>\n<p> \uf0b7The filters must be heat resistant, steam resistant, hydrophobic and pressure resistant for the pressure difference.  <\/p>\n<p> &nbsp; <\/p>\n<p> \uf0b7Cooling down phase after treatment ought to be existent; the temperature of the waste should be not higher than 80\u00b0C <\/p>\n<p> after completing the cooling down process.  <\/p>\n<p> \uf0b7The pressure vessel should be equipped with a heating insulating material, the maximum outer surface temperature should be < 50\u00b0 <\/p>\n<p>after finishing the cooling down process.<\/p>\n<p>\uf0b7The pressure vessel should be equipped with a heat insulation, the maximum outer surface temperature should be &lt; 50\u00b0<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Guide autoclave with vertical loading; gravity displacement type with possibility for Vacuum. &nbsp; Capacity:\u00a0\u00a0\u00a0\u00a0\u00a0 Up to 12 kg\/h &nbsp; Chamber size:\u00a0\u00a0\u00a0\u00a0\u00a0 >150 Dimensions &nbsp; Material:\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Stainless steel &nbsp; [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":2017,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"_links":{"self":[{"href":"https:\/\/gofullday.com\/incineration\/wp-json\/wp\/v2\/posts\/3808"}],"collection":[{"href":"https:\/\/gofullday.com\/incineration\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gofullday.com\/incineration\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gofullday.com\/incineration\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gofullday.com\/incineration\/wp-json\/wp\/v2\/comments?post=3808"}],"version-history":[{"count":1,"href":"https:\/\/gofullday.com\/incineration\/wp-json\/wp\/v2\/posts\/3808\/revisions"}],"predecessor-version":[{"id":9276,"href":"https:\/\/gofullday.com\/incineration\/wp-json\/wp\/v2\/posts\/3808\/revisions\/9276"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gofullday.com\/incineration\/wp-json\/wp\/v2\/media\/2017"}],"wp:attachment":[{"href":"https:\/\/gofullday.com\/incineration\/wp-json\/wp\/v2\/media?parent=3808"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gofullday.com\/incineration\/wp-json\/wp\/v2\/categories?post=3808"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gofullday.com\/incineration\/wp-json\/wp\/v2\/tags?post=3808"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}