{"id":3044,"date":"2024-04-15T05:27:25","date_gmt":"2024-04-15T05:27:25","guid":{"rendered":"https:\/\/www.hiclover.com\/?p=3044"},"modified":"2024-04-15T05:27:25","modified_gmt":"2024-04-15T05:27:25","slug":"00-beds-healthcare-center-incenerator-technical-informations","status":"publish","type":"post","link":"https:\/\/gofullday.com\/incineration\/00-beds-healthcare-center-incenerator-technical-informations\/","title":{"rendered":"00 BEDS HEALTHCARE CENTER INCENERATOR TECHNICAL INFORMATIONS"},"content":{"rendered":"<div class=\"topad\">\n\t\t\t\t\t\t\t\t\t\t<script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js\"><\/script><\/p>\n<\/div>\n<h3>1)\u00a0Policy<\/h3>\n<\/p>\n<p>  &#8211; &#8211; &#8211; &#8211; Incinerator:  <\/p>\n<\/p>\n<h3>2)\u00a0Waste Disposal Plan<\/h3>\n<ol>\n<li>a)Classification<\/li>\n<\/ol>\n<p>  it&#8217;s designed to sanitize medical waste, reduce its amount, and make its components unrecognizable all in one completely restricted in addition to automated system.   <\/p>\n<\/p>\n<table>\n<tbody>\n<tr>\n<td rowspan=\"3\" width=\"106\">Infections Waste<\/td>\n<td width=\"171\">Specially-controlled waste<\/td>\n<td width=\"246\">Organ, needle, etc.<\/td>\n<\/tr>\n<tr>\n<td width=\"171\">Industrial waste<\/td>\n<td width=\"246\">Rubber gloves, etc.<\/td>\n<\/tr>\n<tr>\n<td width=\"171\">General waste<\/td>\n<td width=\"246\">Gauze, etc.<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" width=\"106\">General Waste<\/td>\n<td width=\"171\">Plastic, Rubber<\/td>\n<td width=\"246\">Infusion bottle, etc.<\/td>\n<\/tr>\n<tr>\n<td width=\"171\">Paper, wood, Vinyl<\/td>\n<td width=\"246\">Voucher, etc.<\/td>\n<\/tr>\n<tr>\n<td width=\"171\">Metal, Glass<\/td>\n<td width=\"246\">Can, Glass bottle<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<ol>\n<li>b) Infections Waste Disposal<\/li>\n<\/ol>\n<p>  The contaminated waste is filled up right into the major stainless-steel room where a tough shredder reduces the waste to small items.   <\/p>\n<p>  Treatment cycle:  <\/p>\n<p>  1- Filling up; the contaminated waste is automatically -loaded right into the room of the system  <\/p>\n<p>  2-Shredding; the springy shredder decreased the product right into little items in addition to likewise contains an unique transforming about system to remain clear of blocking <\/p>\n<\/p>\n<p>  3-Heat; saturated pressurized hefty steam raises the temperature to 134 C as well as the stress to 3 bar  <\/p>\n<p>  4-Sterilization; the sanitation gets in directly phone call with the shredding material (134 c, 3 bar) for 20 minutes  <\/p>\n<p>  5-Cooling; fever level is lowered to 80 C by splashing amazing water onto Double coating of the treatment vessel, concurrently, the unit returns to ambient pressure  <\/p>\n<p>  6-Draining; the hefty vapor is compressed to water and released with the cooling water into the sterile sewer system  <\/p>\n<p>  7-vacuum; the residual recurring steam is vented out with a air pump  <\/p>\n<p>  8-Unloading; an electronic sign informs the driver that safe operating problems have been fulfilled <\/p>\n<p>  The issue unlocks the gadget in addition to also allows gravity unloading of the treated waste right into a container  <\/p>\n<p>  Coach Spec  <\/p>\n<p>  General Characteristics  <\/p>\n<p>  8log 10  <\/p>\n<p>  &#8211; &#8211; &#8211; &#8211; Incinerator:  <\/p>\n<p>  it&#8217;s established to sterilize expert waste, reduce its amount, and make its components equal all in one completely enclosed in addition to automated system.   <\/p>\n<p>  The infected waste is filled up right into the top stainless-steel room where a durable shredder lowers the waste to tiny products.   <\/p>\n<p>  Therapy cycle:  <\/p>\n<p>  1- Filling up; the contaminated waste is instantly -loaded into the chamber of the system  <\/p>\n<p>  2-Shredding; the Long-lasting shredder decreased the item right into small pieces and likewise Includes an unique transforming about system to avoid blocking <\/p>\n<p>  3-Heat; saturated pressurized heavy vapor increases the temperature to 134 C and the stress to 3 bar  <\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"226\">Operational temp. max<\/td>\n<td width=\"213\">160 C<\/td>\n<\/tr>\n<tr>\n<td width=\"226\">Max Weight when filld with waste For a special hydraulic test. Kg<\/td>\n<td width=\"213\">10500<\/td>\n<\/tr>\n<tr>\n<td width=\"226\">Stress. Kg\/ cm<sup>3<\/sup><\/td>\n<td width=\"213\">3.5<\/td>\n<\/tr>\n<tr>\n<td width=\"226\">Steam Pressure. Bar<\/td>\n<td width=\"213\">8<\/td>\n<\/tr>\n<tr>\n<td width=\"226\">Max Steam Flow Kg\/h<\/td>\n<td width=\"213\">500<\/td>\n<\/tr>\n<tr>\n<td width=\"226\">Compressed Air Bar<\/td>\n<td width=\"213\">6<\/td>\n<\/tr>\n<tr>\n<td width=\"226\">Electricity 380 V\/3 \u2013 phase Surge Protection system<\/td>\n<td width=\"213\">35KW<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"439\">Operating Characteristics<\/td>\n<\/tr>\n<tr>\n<td width=\"226\">Average Cycle Time. minutes<\/td>\n<td width=\"213\">60<\/td>\n<\/tr>\n<tr>\n<td width=\"226\">Process Wight Capacity . Kg<\/td>\n<td width=\"213\">500 &#8211; 600<\/td>\n<\/tr>\n<tr>\n<td width=\"226\">Density. Kg\/m3<\/td>\n<td width=\"213\">100<\/td>\n<\/tr>\n<tr>\n<td width=\"226\">Average process wight capacity Kg.\/cycle microbial inactivation<\/td>\n<td width=\"213\">200-300<\/p>\n<p>  4-Sterilization; the sterilization gets in directly call with the shredding material (134 c, 3 bar) to get 20 mins  <\/td>\n<\/tr>\n<tr>\n<td width=\"226\">Waste volume reductin<\/td>\n<td width=\"213\">80%<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"439\">Consumption \/ Cycle<\/td>\n<\/tr>\n<tr>\n<td width=\"226\">Steam. Kg<\/td>\n<td width=\"213\">40<\/td>\n<\/tr>\n<tr>\n<td width=\"226\">Electricity . KW\/h<\/td>\n<td width=\"213\">9<\/td>\n<\/tr>\n<tr>\n<td width=\"226\">Water Liters<\/td>\n<td width=\"213\">500<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"bottomad\">\n\t\t\t\t\t\t\t\t\t\t<script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js\"><\/script><\/p>\n<p>  5-Cooling; temperature level is decreased to 80 C by spraying water that is amazing onto Dual coat of the treatment vessel, concurrently, the unit returns to ambient pressure  <\/p><\/div>\n","protected":false},"excerpt":{"rendered":"<p>1)\u00a0Policy &#8211; &#8211; &#8211; &#8211; Incinerator: 2)\u00a0Waste Disposal Plan a)Classification it&#8217;s designed to sanitize medical waste, reduce its amount, and make its components unrecognizable all in one completely [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":2017,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"_links":{"self":[{"href":"https:\/\/gofullday.com\/incineration\/wp-json\/wp\/v2\/posts\/3044"}],"collection":[{"href":"https:\/\/gofullday.com\/incineration\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gofullday.com\/incineration\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gofullday.com\/incineration\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gofullday.com\/incineration\/wp-json\/wp\/v2\/comments?post=3044"}],"version-history":[{"count":1,"href":"https:\/\/gofullday.com\/incineration\/wp-json\/wp\/v2\/posts\/3044\/revisions"}],"predecessor-version":[{"id":9860,"href":"https:\/\/gofullday.com\/incineration\/wp-json\/wp\/v2\/posts\/3044\/revisions\/9860"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gofullday.com\/incineration\/wp-json\/wp\/v2\/media\/2017"}],"wp:attachment":[{"href":"https:\/\/gofullday.com\/incineration\/wp-json\/wp\/v2\/media?parent=3044"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gofullday.com\/incineration\/wp-json\/wp\/v2\/categories?post=3044"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gofullday.com\/incineration\/wp-json\/wp\/v2\/tags?post=3044"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}