news

biohazard waste disposal guidelines

Posted on:

biohazard waste disposal guidelines 1. The ground should be flat when install the incinerator. There should be 100cm at least between the incinerator  and the walls on the two sides and the back, which is in convenient maintenance and repair. 2.  A), Place the incinerator main body(combustion chamber) and fixed with bolts and Asbestos tape. B), Place the wet scrubber system and fixed with bolts and Asbestos tape. C). Install chimneys and fixed with bolts, Asbestos tape and Steel Rope. D). Fix the incineration house roof. E). Fix burner, blower, wind tube, electric system, fuel system. 3. Check the electric wire: the incinerator’s electric circuit should be linked with the ground wire to guard against current leakage.  The link-up of the electric wire should be checked carefully before starting the incinerator, in case of wrong link-up or leakage. 4. Check of the fuel supply system: Except the Burner’s soft pipe which is used for the fuel flowing-in and flowing-back, all the rest pipes must use brass or steel pipe. No leakage is allowed at pipe junctions. Any leakage should be blocked in time. 5. Install steel rope with the chimney, to avoid tilt by wind.  6. Install net cover at the blower, to avoid sundries. 7. If the fuel is Natural Gas with gas burner, please contact with local administration section and install gas supplier system. 8. Crane or forklift is necessary when download/upload/install incinerator.  9. Topped work house roof after installation. 10.Get the video material: http://www.eclover.net/category/incinerator-video/     Nanjing Clover Medical Technology Co.,Ltd. incinerate china orders incinerators hospital waste disposal ppt safe waste incinerator company […]

news

About Us

Posted on:

Nanjing Clover Medical Technology Co.,Ltd. local in Nanjing city, China which is near to Shanghai port. We are Waste Incinerator Manufacturer in China. We produce medical waste incinerators, […]

news

Afghanistan hospital incinerator

Posted on:

hazardous waste disposal incinerator http://www.military-camps-incinerator.com/  Incinerator Items/Model HICLOVER TS100(PLC) HICLOVER TS150(PLC) Burn Rate (Average) 100-150 kg/hour 150-200 kg/hour Feed Capacity(Average) 200kg/feeding 300kg/feeding Control Mode PLC Automatic PLC Automatic […]

news

Incinerator Furnaces for Pet Cremation

Posted on:

Basic Info. Model NO.:incinerator manufacturers in middle east Export Markets:Global Product Description Key Features:  * All models with Dual combustion chamber.  * Stainless Steel chimney/stack, long lifetime. *according […]

news

Oil Waste Incinerator

Posted on:

Basic Info. Model NO.:Pet Crematory Equipment Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Product Description Technology Respond(FAQ)  Q: What is kind of waste can use in this […]

news

Hospital Medical Waste Incinerator

Posted on:

Basic Info. Model NO.:hazardous waste incinerators manufacturer Export Markets:Global Product Description Incinerator is a incineration equipment, direct fire waste by gas fuel or oi fuel. As different circumscription, […]

news

MEDICAL WASTE INCINERATOR

Posted on:

Phone: +86-13813931455(whatsapp/wechat)Website: http://www.gofullday.com/incineration/  Email: [email protected]Email: [email protected]   Nanjing Clover Medical Technology Co.,Ltd. 1. Incinerator 10kg per hr 2. Incinerator 20kg per hr 3. Incinerator 50kg per hr 4. Incinerator 100kg per hr 5. INDOOR INCINERATOR 2021-02-23 Three Combustion Chambers(Optional) 3 […]

news

Small Waste Incinerator

Posted on:

Basic Info. Model NO.:small scale incenaration Export Markets:Global Product Description Nanjing Clover Medical Technology Co., Ltd.. Key Features:  * All versions with Dual combustion chamber.  * Stainless Steel […]

news

Hospital Incinerator

Posted on:

Basic Info. Export Markets:Global Additional Info. Trademark:clover Product Description Items Specification Model TS10(PLC) / TS20(PLC) / TS30(PLC) / TS50(PLC) / TS100(PLC) Main Product List Double Combustion Chamber Smoke […]

news

Incineraot Msw2000

Posted on:

Basic Info. Model NO.:MSW2000 Export Markets:Global Additional Info. Trademark:CLOVER Product Description Nanjing Clover Medical Technology Co., Ltd.. Items Specification  Model MSW2000 / MSW3000 / MSW4000 / MSW5500 Main […]

news

Containerized Mobile Kind Tool Device Waste Burner

Posted on:

Medium Unit – to handle an average waste production of 500 kg/day.Minimum load capacity: 600 kg.Maximum load capacity: 1,000 kg.Nominal burning rate: 55-80 kg/hr (= 440 C 640kg range per 8hour day). Items/Model TS50( PLC) Image Idea Waste Incineration Therapy Melt Price Criterion 50-100 kg/hour Feed Capability Typical 200-300 kg/feeding Control Mode PLC( Programmable Reasoning Controller Burner) Optional Upgrade […]

news

Incineration plant machine of 150kg/hr on LPG

Posted on:

Incineration plant machine of 150kg/hr On Lpg Items/Model TS150(PLC) Picture   Principle Medical Waste Incineration Treatment Burn Rate Average 150 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1500L […]

news

GENERAL SPECIFICATIONS FOR BURNERS

Posted on:

lnsulation: lnsulation to be utilized for stonework, increased concrete, or non-combustible product will protect against damages to the structure from intense warm and shall be of a depth […]

news

animal incinerator china

Posted on:

Medical Waste Shredder    Ability: Should be 150 liters.  Should be capable to shred up to 100 liters of the treated waste. 7  The technology […]

news

Animal Incinerators

Posted on:

Basic Info. Model NO.:animal incinerator manufacturers Export Markets:Global Product Description Items/Model YD-10C YD-20C YD-30C YD-50C Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr. Feed Capacity […]

news

Incinerator

Posted on:

Basic Info. Export Markets:Global Additional Info. Trademark:CLOVER Product Description Program Scope:  1. Incinerator is a incineration equipment, direct fire waste by gas fuel or oi fuel. As distinct […]

news

Medium Scale Solid Waste Incinerator

Posted on:

Double Combustion Chamber,Double Italy Burner,Smoke Filter Included,Burning Rate: 50-200kgs per hour optional,Primary Combustion Chamber: 1.57M3(1570Liters),Incinerator Mainbody steel: 8mm thickness,Paint for outside face: 800°C Rate,Chamber Material: High Alumina Fire […]

news

hiclover 10kgs per hour incinerator

Posted on:

Smallest waste incinerator for small hospital  average 10kgs per hour.  with double(2) sets burner. Equipment Technical Specifications Model YD-10 Feed Capacity Average 20 kgs per feed Burning Rate […]

news

Hospital Medical Waste Incinerators

Posted on:

Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type Qty. Ready for Shipping New Production  Shipping Volume Shipping Weight Delivery Location TS30 average 30kgs per hour Average 150 […]